Chiller
1. Fiber laser water cooler
(1) Application scope
●Suitable for all kinds of fiber lasers such as laser cladding, welding and cutting.
●Applicable to various fiber lasers such as laser marking and 3D printing.
(2) Functions and features
●Using high-quality stainless steel submerged cold water circulation pump, it has large flow, high head, low noise, no leakage and long service life; the plastic water tank, stainless steel pipeline and valve parts will never worry about rusting;
●The control system uses an analog input digital indicator to display the cooling water temperature in real time, and the operation is simple and intuitive. The water temperature control accuracy is ±0.1°C-1°C; it has the function of automatic fault diagnosis, directly displays the fault point on the screen, and prompts the user to deal with it quickly;
●Provide multiple protection functions and passive alarm terminals.
Among them, the "dual temperature" water cooler not only provides stable and accurate water temperature control for the laser, but also provides a channel of water temperature close to the ambient temperature for lens cooling, which solves the problem of lens damage caused by condensation when cooling with low-temperature water One problem, it is the best choice for cooling the whole laser equipment.
AS - L1500 - A1
Technical Data Sheet
Item\Model |
|
AS-L1500 |
|
---|---|---|---|
Power supply |
V,Hz |
AC220V/50Hz |
|
Rated power |
kW |
1.6 |
|
Rated current |
A |
7 |
|
Cryogenic pump flow |
L/min |
27 |
|
Cryogenic water pump head |
m |
37 |
|
Room temperature water pump flow |
L/min |
2 |
|
Head of water pump at room temperature |
m |
37 |
|
Water temperature range |
℃ |
Low temperature water: 18~30℃, control accuracy ±1℃ Room temperature water: 20-40°C, control accuracy ±1°C |
|
Recycled water |
|
Use deionized water or bottled drinking pure water | |
Ambient temperature |
℃ |
5~42℃ |
|
Noise |
dB(A) |
≤65 |
≤72 |
Degree of protection |
|
IP44 |
|
|
Outlet(G) |
1/2″ |
|
Low temperature water | |||
Connection size | |||
|
Backwater(G) |
1/2″ |
|
|
Outlet(G) |
1/2″ |
|
Room temperature water | |||
Connection size | |||
|
Backwater(G) |
1/2″ |
|
Dimensions W*D*H |
mm |
590×460×950 |
|
Tank volume |
L |
27 |
|
Weight |
kg |
70 |
|
Note: The cooling capacity is measured under the working condition of ambient temperature 35°C and outlet water temperature 22°C;
For special requirements, please contact our company.
AS - L2000 - A1
Technical Data Sheet
Item\Model |
|
AS-L2000 |
|
---|---|---|---|
Power supply |
V,Hz |
AC220V/ 50Hz |
|
Rated power |
kW |
2.2 |
|
Rated current |
A |
10 |
|
Cryogenic pump flow |
L/min |
27 |
|
Cryogenic water pump head |
m |
37 |
|
Room temperature water pump flow |
L/min |
2 |
|
Head of water pump at room temperature |
m |
37 |
|
Water temperature range |
℃ |
Low temperature water: 18~30℃, control accuracy ±1℃ Room temperature water: 20-40°C, control accuracy ±1°C |
|
Recycled water |
|
Use deionized water or bottled drinking pure water | |
Ambient temperature |
℃ |
5~45℃ |
|
Noise |
dB(A) |
≤65 |
≤72 |
Degree of protection |
|
IP44 |
|
|
Outlet(G) |
1/2″ |
|
Low temperature water | |||
Connection size | |||
|
Backwater(G) |
1/2″ |
|
|
Outlet(G) |
1/2″ |
|
Room temperature water | |||
Connection size | |||
|
Backwater(G) |
1/2″ |
|
Dimensions W*D*H |
mm |
640×520×960 |
|
Tank volume |
L |
27 |
|
Weight |
kg |
80 |
|
Note: The cooling capacity is measured under the working condition of ambient temperature 35°C and outlet water temperature 22°C;
For special requirements, please contact our company.
AS - L3000 - A1
Technical Data Sheet
Item\Model |
|
AS-L3000 |
|
---|---|---|---|
Power supply |
V,Hz |
AC220/ 50Hz |
|
Rated power |
kW |
3 |
|
Rated current |
A |
13.5 |
|
Cryogenic pump flow |
L/min |
35 |
|
Cryogenic water pump head |
m |
37 |
|
Room temperature water pump flow |
L/min |
2 |
|
Head of water pump at room temperature |
m |
37 |
|
Water temperature range |
℃ |
Low temperature water: 18~30℃, control accuracy ±1℃ Room temperature water: 20-40°C, control accuracy ±1°C |
|
Recycled water |
|
Use deionized water or bottled drinking pure water | |
Ambient temperature |
℃ |
5~45℃ |
|
Noise |
dB(A) |
≤65 |
≤72 |
Degree of protection |
|
IP44 |
|
|
Outlet(G) |
1/2″ |
|
Low temperature water | |||
Connection size | |||
|
Backwater(G) |
1/2″ |
|
|
Outlet(G) |
1/2″ |
|
Room temperature water | |||
Connection size | |||
|
Backwater(G) |
1/2″ |
|
Dimensions W*D*H |
mm |
690×560×970 |
|
Tank volume |
L |
27 |
|
Weight |
kg |
100 |
|
Note: The cooling capacity is measured under the working condition of ambient temperature 35°C and outlet water temperature 22°C;
For special requirements, please contact our company.
AS - L6000 - A1
Technical Data Sheet
Item\Model |
|
AS-L6000 |
|
---|---|---|---|
Power supply |
V,Hz |
AV380/ 50Hz |
|
Rated power |
kW |
8 |
|
Rated current |
A |
18 |
|
Cryogenic pump flow |
L/min |
60 |
|
Cryogenic water pump head |
m |
60 |
|
Room temperature water pump flow |
L/min |
2-5 |
|
Head of water pump at room temperature |
m |
60 |
|
Water temperature range |
℃ |
Low temperature water: 18~30℃, control accuracy ±1℃ Room temperature water: 20-40°C, control accuracy ±1°C |
|
Recycled water |
|
Use deionized water or bottled drinking pure water | |
Ambient temperature |
℃ |
5~45℃ |
|
Noise |
dB(A) |
≤65 |
≤72 |
Degree of protection |
|
IP44 |
|
|
Outlet(G) |
1″ |
|
Low temperature water | |||
Connection size | |||
|
Backwater(G) |
1″ |
|
|
Outlet(G) |
1/2″ |
|
Room temperature water | |||
Connection size | |||
|
Backwater(G) |
1/2″ |
|
Dimensions W*D*H |
mm |
1020×530×1120 |
|
Tank volume |
L |
60 |
|
Note: The cooling capacity is measured under the working condition of ambient temperature 35°C and outlet water temperature 22°C;
For special requirements, please contact our company.
AS - L12000 - A1
Technical Data Sheet
Item\Model |
|
AS-L12000 |
|
---|---|---|---|
Power supply |
V,Hz |
AV380/ 50Hz |
|
Rated power |
kW |
15 |
|
Rated current |
A |
25 |
|
Cryogenic pump flow |
L/min |
160 |
|
Cryogenic water pump head |
m |
60 |
|
Room temperature water pump flow |
L/min |
2-5 |
|
Head of water pump at room temperature |
m |
60 |
|
Water temperature range |
℃ |
Low temperature water: 18~30℃, control accuracy ±1℃ Room temperature water: 20-40°C, control accuracy ±1°C |
|
Recycled water |
|
Use deionized water or bottled drinking pure water | |
Ambient temperature |
℃ |
5~45℃ |
|
Noise |
dB(A) |
≤65 |
≤72 |
Degree of protection |
|
IP54 |
|
|
Outlet(G) |
1-1/4″ |
|
Low temperature water | |||
Connection size | |||
|
Backwater(G) |
1-1/4″ |
|
|
Outlet(G) |
1/2″ |
|
Room temperature water | |||
Connection size | |||
|
Backwater(G) |
1/2″ |
|
Dimensions W*D*H |
mm |
1230×750×1450 |
|
Tank volume |
L |
150 |
|
Note: The cooling capacity is measured under the working condition of ambient temperature 35°C and outlet water temperature 22°C;
For special requirements, please contact our company.